Side outlet DC frequency conversion rotary compressor chiller

DC Inverter Mini Chiller with Rotary Compressor Product featuresHigh efficiencyA+ rated energy efficiencyStructurePanels and base frame are made from galvanized steel protected with polyester powder painting to ensure total resistance to atmospheric agents.CompressorTwin rotary DC inverter compressor is used.The output of t

Featured Products

DC Inverter Mini Chiller with Rotary Compressor

Side Discharge DC Inverter Rotary Compressor Water Chiller
 
Product features
High efficiency
A+ rated energy efficiency
Side Discharge DC Inverter Rotary Compressor Water Chiller


Structure
Panels and base frame are made from galvanized steel protected with polyester powder painting to ensure total resistance to atmospheric agents.

Compressor
Twin rotary DC inverter compressor is used.
The output of the outdoor unit can be adjusted precisely according to the energy demanded.

> Compressor (Twin Rotary) structure
Side Discharge DC Inverter Rotary Compressor Water Chiller


Axial fan
High efficiency DC fan motor saved power up to 50%.
Side Discharge DC Inverter Rotary Compressor Water Chiller


Evaporator
High efficiency plate heat exchanger, factory insulated with flexible close cell material.
Side Discharge DC Inverter Rotary Compressor Water Chiller

Condenser
Coils are consisting of seamless copper tubes mechanically expanded into blue hydrophilic aluminum fins, protected with flexible plastic grill.

 
Side Discharge DC Inverter Rotary Compressor Water Chiller
The new designed window fins enlarge the heatexchanging area, decrease the air resistance, save more power and enhance heat exchange performance.
Hydrophilic film fins and inner-threaded copper pipes optimize heat exchange efficiency.
The specially coated blue fins enhance durability and protect against corrosion from air, water and other corrosive agents, assures a longer coil service life.


Easy installation
Compact structure design and leak-tight refrigerant circuit save you much installation labor.
The chillers are equipped with a hydronic module integrated into the unit chassis, limiting the installation to straight-forward operations like connection of the power supply, the water supply and the air distribution FCUs.
The units are equipped with axial fans so they can be installed directly outdoors.

> Hydraulic module
Side Discharge DC Inverter Rotary Compressor Water Chiller
 
Easy control
Remote ON/OFF and remote cool/heat functions.
Side Discharge DC Inverter Rotary Compressor Water Chiller

Controller built-in in unit panel used to perform all related operations as the user interface as well as fast diagnosis of possible incidents and their history.
> ON/OFF & Mode selection
> Temperature adjust
> Timer setting
> Fast diagnosis
Side Discharge DC Inverter Rotary Compressor Water Chiller

Optional wired controller for easy operation.
> Touch key operation
> LCD displays operation parameters
> Multiple timers
> Real-time clock
Side Discharge DC Inverter Rotary Compressor Water Chiller
Note: When the wired controller is connected, the built-in controller is only for display, check and diagnosis functions.


Optional
Hydraulic module, including flow switch, water pump and expansion vessel (For model AW30 only).
 
Specifications
ModelAW5AW7AW10AW12
CapacityCoolingkW571010.511.2
Power inputkW1.552.252.953.113.5
EER 3.233.113.393.383.2
HeatingkW6.281111.112.3
Power inputkW1.92.53.143.143.78
COP 3.263.23.53.543.25
CompressorType Rotary
Qty 1
Axial fanType DC motor
Qty 12
Air flow ratem3/h32003750480070004800
Control methods EXV
Evaporator type Plate heat exchanger
Water flowm3/h0.861.21.721.811.93
Pipe connection size 1 inch1-1/4 inch
Water resistancekPa1515181818
Refrigerant Type R410A
Charge quantitykg2.52.52.82.82.8
Power supply 220~240V/1Ph/50Hz208~230V/1Ph/60Hz220~240V/1Ph/50Hz
Net dimensions (W×H×D)mm1008x963x3961008x963x396970x1327x400970x1327x400970x1327x400
Unit shape Side discharge
Noise leveldB(A)6366685668
Net weightkg8181110110110
 
ModelAW12AW14AW16AW18AW30
CapacityCoolingkW11.212.514.51727
Power inputkW3.383.94.75.610.8
EER 3.313.23.13.042.5
HeatingkW12.313.81618.531
Power inputkW3.724.254.855.7810.5
COP 3.313.253.33.22.95
CompressorType Rotary
Qty 1
Axial fanType DC motor
Qty 21
Air flow rate 480048006200700012500
Control methods EXV
Evaporator type Plate heat exchanger
Water flowm3/h1.922.152.492.925
Pipe connection size 1-1/4 inchDN40
Water resistancekPa1818192355
Refrigerant Type R410A
Charge quantitykg2.82.93.23.410.5
Power supply 380~415V/3Ph/50Hz208~230V/1Ph/60Hz380~415V/3Ph/50Hz
Net dimensions (W×H×D)mm970x1327x4001870x1000x1175
Unit shape Side dischargeTop discharge
Noise leveldB(A)6870726078
Net Weightkg110111111112300
Note:
1. Cooling: Chilled water inlet/outlet temp.12/7°C; outdoor ambient temp. 35°C DB.
2. Heating: Warm water inlet/outlet temp. 40/45°C; outdoor ambient temp. 7°C DB/6°C WB.
3. Sound pressure level is measured at a position 1m in front of the unit and 1.1m above the floor in a semi-anechoic chamber.
4. Capacity and efficiency data calculated in accordance with EN14511; EN14825.

Product Catalogue
Side Discharge DC Inverter Rotary Compressor Water Chiller

Project
Side Discharge DC Inverter Rotary Compressor Water Chiller


 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours